Abstract: | A microfluidic paper-based impedimetric device was developed as a
water hardness sensor. This device is capable of performing the
analysis with a sample volume of a few microliters with no prior
treatments. A phenol-formaldehyde graphene electrode modified with
ethylenediaminetetraacetate was used as the working electrode. Ag
pseudo reference and carbon electrodes were used to fabricate the
device. Current simultaneous metal ion detection sensors are based on
complex and expensive electrode setups. The proposed inexpensive,
quick and portable device is capable of detecting Ca2+ and Mg2+
simultaneously. Electrode double layer-based charge transfer
resistance and the maximum negative imaginary impedance produced a
linear correlation with each metal ion concentration. The calculated
limits of detection for Ca2+ and Mg2+ were 0.31 and 0.24 ppm,
respectively. A set of samples containing Ca2+ and Mg2+ with a
hardness of 2 ppm (as calcium carbonate) were used to test the device.
The proposed tool is suitable as a semi-quantitative device for the
determination of hardness in water. A microfluidic paper-based impedimetric device was developed as a water hardness sensor. This device is capable of performing the analysis with a sample volume of a few microliters with no prior treatments. A phenol-formaldehyde graphene electrode modified with ethylenediaminetetraacetate was used as the working electrode. Ag pseudo reference and carbon electrodes were used to fabricate the device. Current simultaneous metal ion detection sensors are based on complex and expensive electrode setups. The proposed inexpensive, quick and portable device is capable of detecting Ca2+ and Mg2+ simultaneously. Electrode double layer-based charge transfer resistance and the maximum negative imaginary impedance produced a linear correlation with each metal ion concentration. The calculated limits of detection for Ca2+ and Mg2+ were 0.31 and 0.24 ppm, respectively. A set of samples containing Ca2+ and Mg2+ with a hardness of 2 ppm (as calcium carbonate) were used to test the device. The proposed tool is suitable as a semi-quantitative device for the determination of hardness in water. |
URI: | http://archive.cmb.ac.lk:8080/xmlui/handle/70130/6299 |
ISSN: | 2620-8571 |
Appears in Collections: | Department of Chemistry |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
49447-75676649809-1-PB.pdf | 670.49 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.